Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 3.5 | 30 | ± 5% | ± 1% | 70mV |
-5V | 0.05 | 0.7 | ± 5%/-10% | ± 1% | 120mV |
+12V | 2 | 32 | +6% | ± 1% | 120mV |
-12V | 0.05 | 0.7 | +5/-10% | ± 1% | 120mV |
+3.3V | 1 | 24 | ± 5% | ± 1% | 70mV |
+5VSB | 0.1 | 2.0 | +5%/-6% | ± 1% | 70mV |
* TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃,STORAGE -20℃ ~ 70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
* HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & 90VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
* EFFICIENCY: 68% TYPICAL, AT FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER LOAD PROTECTION: 110~160% MAX
* OVER VOLTAGE PROTECTION: +5V → 5.7V ~ 6.5V, +3.3V →3.9V~4.3V,+12V → 13.3V ~ 14.3V * OVER CURRENT PROTECTION * EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: UL, CUL, TÜV, CCC, GOST, BSMI
* REMOTE ON / OFF CONTROL
* FAULTY ALARM METHODS:LED, BUZZER, TTL SIGNAL
* MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC)
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* REMOTE SENSING DESIGN
* ISOLATION:BUILT-IN THE POWER MODULE
* AC INLET IN EACH MODULE
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.