VOLTAGE: 90 ~ 264 VAC FULL RANGE. FREQUENCY: 47 ~ 63 Hz. INPUT CURRENT: 4A (RMS) FOR 230 VAC 8A (RMS) FOR 115 VAC INRUSH CURRENT: 50A MAX. FOR 115 VAC PER MODULE 100A MAX. FOR 230 VAC PER MODULE
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
1
24
±5%
±1%
50mV
+12V
2
26
±5%
±1%
120mV
-12V
0.05
0.8
±5%
±1%
150mV
+3.3V
1
20
±5%
±1%
50mV
+5VSB
0.1
3
±5%
±1%
50mV
Features...
‧TEMPERATURE RANGE: OPERATING 0℃ --- 40℃,STORAGE -20℃ --- 70℃ ‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE ‧DIELECTRIC WITHSTANDING: INPUT/OUTPUT 1500 VAC FOR 1 MINUTE ‧INPUT TO FRAM GROUND 1500 VAC FOR 1 MINUTE ‧EFFICIENCY: 70% TYPICAL, AT FULL LOAD ‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms ‧OVER LOAD PROTECTION: 110 ~ 160% MAX ‧OVER VOLTAGE PROTECTION: +5V → 5.7V ~ 6.5V, +3.3V → 3.9V ~ 4.3V, +12V → 13.3V ~ 14.3V ‧SHORT CIRCUIT: 5V, 12V, 3.3V,AUTO-RECOVERED: 5VSB, -12V ‧EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B ‧SAFETY: MEET UL 60950, CSA 60950, TUV EN-60950 ‧REMOTE ON / OFF CONTROL ‧FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL ‧HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION ‧MEET IEC-1000-3-2 CLASS D (ACTIVE PFC) ‧N+1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL ‧REMOTE SIGNAL DESIGN ‧ISOLATION: BUILT-IN THE POWER MODULE ‧DIMENSION: 276 x 101 x 82 (D*W*H) mm ‧I2C FEATURES (OPTIONAL) ‧COOLING: TWO 40 mm DC FANS (ONE IN EACH MODULE)
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.