VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:2A (RMS) FOR 115 VAC 1A (RMS) FOR 230 VAC INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE 70A MAX. FOR 230 VAC PER MODULE
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
10
±5%
±1%
50mV
+12V
2
10
±5%
±1%
120mV
+3.3V
0
10
± 5%
±1%
50mV
-12V
0
0.3
±10%
± 1%
120mV
+5VSB
0.1
3
±5%
±1%
50mV
Features...
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230 V AND FULL LOADING(+12V:10A). * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC * REMOTE ON/OFF CONTROL * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY: MEET UL&CUL, TUV, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.