800W Server ,Workstation ,Storage System ,IPC ,Blade server ,PCs ,Communication ,Networking
Dimension....
200x101.2x84(mm) 7.87x3.98x3.31(inch)
AC Input Spec...
VOLTAGE: 90~264 Vac FULL RANGE FREQUENCY: 47~63 Hz INPUT CURRENT:12A (RMS) FOR 115V / 6A (RMS) FOR 230V INRUSH CURRENT:15A MAX. FOR 115V / 30A MAX. FOR 230V
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
36
±5%
±1%
50mV
+12V
2
66
±5%
±1%
120mV
+3.3V
0
31
±5%
±1%
50mV
-12V
0
0.5
±5%
±1%
120mV
+5VSB
0.1
3
±5%
±1%
50mV
* +5V AND +3.3V Max. POWER:210W * TOTAL POWER: 800W (MAX)
Features...
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 10MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY: THE MAXMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 85%, MEASURED AT NOMINAL INPUT VOLTAGE 115V OR 230V AND FULL LOADING. * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 240VAC * REMOTE ON/OFF CONTROL * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION: The power supply shall provide over power protection on the power supply latches all DC output into a shutdown state. Over power of this type shall cause no damage to power supply, after over load is removed and a power on/off cycle is initiated, the power supply will restart. Trigger point total power MIN. 105%, MAX. 150%. * OVER VOLTAGE PROTECTION: +5V → 5.7~6.5V, +3.3V → 3.7~4.1V, +12V → 12.8~13.9V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * OVER CURRENT PROTECTION * SAFETY: TO MEET UL, CUL, TUV, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.