VOLTAGE: 100~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6.5A (RMS) FOR 115 VAC / 3.5A (RMS) FOR 230 VAC INRUSH CURRENT:30A MAX. FOR 115 VAC PER MODULE / 60A MAX. FOR 230 VAC PER MODULE PFC: Up to the target of 95% @115V & 90% @230V, full load
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+54V
1
9
±5%
±1%
540mV
+5VSB
0.1
2.5
±5%
±1%
50mV
Features...
* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 13mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY:Shall be 88.6%, measured at nominal input voltage 230V and full loading * LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 250VAC * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +54V→+59.4~+70.2V * SHORT CIRCUIT PROTECTION * SAFETY: MEET UL 60950, CUL, TUV EN-60950, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.