VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:4A(RMS)FOR 230VAC, 8A(RMS)FOR 115VAC INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE, 60A MAX. FOR 230 VAC PER MODULE
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
32
±5%
±1%
60mV
+12V
2
40
±5%
±1%
120mV
-12V
0
1
±5%
±1%
120mV
+3.3V
0
25
±5%
±1%
60mV
+5VSB
0.1
3.5
±5%
±1%
60mV
Features...
* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃ * HOLD UP TIME:16mS MIN. AT FULL LOAD & 90 VAC INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute INPUT TO FRAME GROUND 1500 VAC FOR 1 minute * EFFICIENCY:80% TYPICAL AT 115V, 82% TYPICAL AT 230V, FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION:+5V→5.7V~6.5V,+3.3V→3.7V~4.1V ,+12V→12.8V~13.9V * OVER CURRENT PROTECTION: +5V, +12V, +3.3V: 110~150% * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, AUTO-RECOVERED: -12V, +5VSB * EMI : FCC CLASS B , CISPR 22 CLASS B * SAFETY:TO MEET UL, CUL, TUV * FAULTY ALARM METHODS: TTL SIGNAL * REMOTE SENSING DESIGN * REMOTE ON/OFF CONTROL * ISOLATION: BUILT-IN THE POWER MODULE * COOLING: TWO 40x40x28mm DC FANS * AC INLET IN EACH MODULE
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.