* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃; OPERATING TEMPERATURE FROM 0℃ SHOULD START FROM DC -48V * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 1.6mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND * EFFICIENCY:>80% AT -48V,FULL LOAD * HUMIDITY: OPERATING HUMIDITY: 20%~80%; NON-OPERATING HUMIDITY: 10%~90% * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION: +12V→13.2V~15.6V * SHORT CIRCUIT PROTECTION: +12V, -12V; AUTO-RECOVERED: +5VSB * EMI NOISE FILTER : CISPR22 CLASS A * SAFETY : TO MEET UL60950, TUV EN-60950, CB IEC 60950 * REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.