ATN-5400V(400W)

详细说明


400W

Server ,Workstation ,Storage System ,IPC


Dimension....
265x79x40.5(mm)
10.43x3.11x1.59(inch)

AC Input Spec...
VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 6/3 AMPS MAXIMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 25A MAX. FOR 110 VAC PER MODULE,
50A MAX. FOR 220 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95%
@ 115V, FULL LOAD, FOLLOWING THE STANDARD OF
IEC 1000-3-2


DC Output Spec...
Output VoltageTDOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noise Max.[P-P]
+5V1.032±5%±1%50mV
+12V2.033±5%±1%120mV
-12V0.00.5±5%±1%120mV
+3.3V1.025.0±5%±1%50mV
+5VSB0.13.5±5%±1%50mV
* POWER MODULE TOTAL OUTPUT POWER OF +5V AND +3.3V NOT EXCEED 170W
* TOTAL OUTPUT POWER NOT EXCEED 400W


Features...
* TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
* EFFICIENCY: 86%(MAX)
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OUTPUT PROTECTION: OPP / OVP / OCP / SCP
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* ISOLATION: BUILT-IN THE POWER MODULE
* REMOTE SENSING DESIGN
* SAFETY: TO MEET UL, CUL, TUV, CCC, RFI/EMI STANDARDS

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.