VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 7A/3A @ 115/230 VAC INRUSH CURRENT: 25/50 AMPS @115/230 VAC (AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT) POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95%@115V AND 90%@230V, FULL LOAD, FOLLOWING THE STANDARD OF IEC61000-3-2 CLASS D
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+12V
1.0
37
±5%
±1%
120mV
+5VSB
0.1
3
±5%
±1%
50mV
* TOTAL POWER: 450W (MAX)
Features...
* TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃ * HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE * EFFICIENCY: THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 87.8%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING. * OUTPUT PROTECTION: OPP / OVP / OCP / SCP * REMOTE ON/OFF CONTROL * LEAKAGE CURRENT: 3.5mA. RMS. MEASUREMENT WILL BE MADE AT 240VAC AND 60HZ
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.