VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 6/3A AT ANY LOW/HGIH RANGE INPUT VOLTAGE INRUSH CURRENT: 30A/60A @115/230VAC POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% @115V, FULL LOAD, FOLLOWING THE STANDARD
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
* TOTAL CURRENT OF V1 AND V2 NOT EXCEED EACH MAX LOAD (FOR EXAMPLE: +12V1 & +12V2 NOT EXCEED 30A) * TOTAL OUTPUT POWER OF V1 AND V2 NOT EXCEED 400W * THE OUTPUT CURRENT OF 5V & 3.3V NOT EXCEED 40A
Features...
* TEMPERATURE RANGE:OPERATING 0℃~50℃ * HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND * EFFICIENCY:TYPICAL 80-83% AT 25℃ 115V FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION:+5V→5.6V~6.5V, +3.3V→3.6V~4.3V, +12V→13.2V~15V * SHORT CIRCUIT PROTECTION:+5V、+12V、+3.3V * RESTART AFTER PROTECTION: OPP/OVP * EMI NOISE FILTER : FCC CLASS A, CISPR22 CLASS A * SAFETY: TO MEET UL, CUL, TUV, CCC * REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE. * 3.3V & 5V REMOTE SENSING * COOLING: ONE 40mm DC FANS * MEET IEC-1000-3-2 CLASS D
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.