VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 12 A ( RMS ) FOR 115VAC / 6A ( RMS ) FOR 230VAC INRUSH CURRENT: 20A MAX. FOR 115 VAC / 40A MAX. FOR 230 VAC PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0.5
25
±5%
±1%
50mV
+12V
1
60
±5%
±1%
120mV
-12V
0
0.8
±5%
±1%
120mV
+3.3V
0.5
25
±5%
±1%
50mV
+5VSB
0.1
3.5
±5%
50mV
Features...
* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃ * HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * HUMIDITY: OPERATING:20%-80%, NON-OPERATING:10%-90% * EFFICIENCY: TYPICAL 80-85% AT 25℃ 115V FULL LOAD * OVER POWER PROTECTOIN: 110%~150% * OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.8~6.7V, +12V→13.2~15V * OVER CURRENT PROTECTION: +3.3V→29.7~40.2A, +5V→29.7~40.2A, +12V→63.7~86.2A * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * RESTART AFTER PROTECTION: IF THE PSU IS USING AC POWER SWITCH TO CONTROL ON/OFF, IT HAS TO BE SWITCHED OFF AT LEAST FOR 5 SECONDS TO RESTART THE UNIT * SAFETY: TO MEET UL, CUL, TUV, CCC * COOLING: ONE 60 mm DC FAN
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.