VOLTAGE: 90~264 VAC FULL RANGE FREQUENCY: 47~63HZ STEADY-STATE CURRENT: 2A/1A AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 35/70 AMPS @115/230 VAC (AT25 DEGREES AMBIENT COLD START) POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% @115/230 VAC, FULL LOAD.
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
14
±5%
±1%
50mV
+12V
0.1
12
±5%
±1%
50mV
-12V
0
0.5
±10%
±1%
120mV
+3.3V
0
12
±5%
±1%
50mV
+5VSB
0
3
±5%
±1%
50mV
Features...
* TEMPERATURE: OPERATING 0 TO 70 DEGREES CENTIGRADE(90~264 VAC);NON-OPERATING TEMPERATURE: -20 TO 80 DEGREES CENTIGRADE * EFFICIENCY: 85%(+/-2%) AT 230V; LOAD CONDITION: 12V/11.18A; 5V/6.47A; 3.3V/5.53A; -12V/0.36A; 5VSB/2.17A * HOLD UP TIME: WHEN AC SOURCE SHUTDOWN DC OUTPUT MUST BE MAINTAIN 100MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE (AC115V@80% OF FULL LOAD). * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION: +3.3V→3.6V~4.3V, +5V→5.6V~6.5V, +12V→13.2~15V * SHORT CIRCUIT: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY: TO MEET UL, CUL, TUV, CCC * LEAKAGE CURRENT: 3.5 mA MAX. AT NOMINAL VOLTAGE 264VAC * REMOTE ON/OFF CONTROL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.