VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:6A (RMS) FOR 115 VAC 3A (RMS) FOR 230 VAC INRUSH CURRENT:30 AMPS @ 230 VAC (AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
5
±5%
±1%
50mV
+12V
1
33
±5%
±1%
120mV
+5VSB
0.1
3
±5%
±1%
50mV
* +5V: option * TOTAL POWER: 400W(MAX)
Features...
‧TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ ‧HOLD UP TIME:16mS MINIMUM AT 115V FULL LOAD ‧EFFICIENCY:90% TYPICAL,AT FULL LOAD 230V ‧REMOTE ON/OFF CONTROL ‧LEAKAGE CURRENT: INPUT LEAKAGE CURRENT FROM LINE TO GROUND WILL BE LESS THAN 3.5MA RMS. MEASUREMENT WILL BE MADE AT 240 VAC AND 60HZ. ‧POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS ‧OVER POWER PROTECTION:110~160% MAX ‧OVER VOLTAGE PROTECTION: +12V→ 13.2~15V ‧SHORT CIRCUIT PROTECTION: +12V, +5VSB ‧SAFETY : TO MEET UL, CUL, TUV, CCC
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.