500W Server ,Workstation ,Storage System ,IPC ,Blade server
Dimension....
170x81.5x40.3(mm) 5.91x3.21x1.59(inch)
AC Input Spec...
VOLTAGE: 110~240VAC(WITH +/-10% TOLERANCE) FREQUENCY: 47~63HZ INPUT CURRENT:6.5 / 3.0 AMPS MAXIMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+12V
2
41
±5%
±1%
120mV
+5VSB
0.1
2.5
±5%
±1%
50mV
Features...
* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 12mSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY:>80% AT 115VAC, 40%~100% MAX LOAD * LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +12V→13~16V * SHORT CIRCUIT PROTECTION: +12V, +5VSB * SAFETY: MEET UL&CUL, TUV, CB, CCC * REMOTE ON/OFF CONTROL * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.