130W Server ,Workstation ,Storage System ,IPC ,Blade server
Dimension....
120x81.5x40.3(mm) 4.72x3.21x1.59(inch)
AC Input Spec...
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT: 2 / 1 AMPS MAXUMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 35/70 AMPS @115/230VAC (HIGH-FREQUENCY PEAK AMPLITUDES LASTING LESS THAN 50uS. SHALL BE IGNORED)
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+48V
0.1
2.71
±5%
±1%
480mV
* TOTAL OUTPUT MAX: 130W
Features...
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:+12V MUST BE MAINTAIN 17mS IN REGULATION LIMIT AT 115V INPUT VOLTAGE * EFFICIENCY:88% AT 230VAC FULL LOAD * LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION: +48V→52~58V * OVER CURRENT PROTECTION: +48V→110~150% * SHORT CIRCUIT PROTECTION: +48V * SAFETY: MEET UL, TUV, CCC * REMOTE ON/OFF CONTROL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.