120W Server ,Workstation ,Storage System ,IPC ,Blade server
Dimension....
120x81.5x40.3(mm) 4.72x3.21x1.59(inch)
AC Input Spec...
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:2A(RMS) FOR 115 VAC / 1A(RMS) FOR 230 VAC INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE / 70A MAX. FOR 230 VAC PER MODULE
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+12V
1
10
±5%
±1%
120mV
+5V
0
10
±5%
±1%
50mV
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 120W
Features...
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT +12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY:85% AT 230VAC, 50% MAX LOAD * LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms * OVER POWER PROTECTION:105~150% MAX * OVER VOLTAGE PROTECTION: +12V→12.8~15V; +5V→5.7~7V * OVER CURRENT PROTECTION: +12V→110~150% * SHORT CIRCUIT PROTECTION: +12V * SAFETY: MEET UL, CUL, TUV, CCC
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.)