VOLTAGE: 90 ~ 240 VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT: 8.5/4.5A FOR 115/230VAC INRUSH CURRENT: 35/80 MAX. FOR 115/230VAC
DC Output Spec...
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0
25
±5%
±1%
50mV
+12V
0.5
50
±5%
±1%
120mV
-12V
0
0.5
±5%
±1%
120mV
+3.3V
0
20
±5%
±1%
50mV
+5VSB
0
3
±5%
±1%
50mV
* TOTAL OUTPUT CURRENT OF +5V AND +3.3V NOT EXCEED 135W * TOTAL POWER: 600W(MAX)
Features...
*TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE -20℃ ~ 80℃ *HOLD UP TIME: 16ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE *EFFICIENCY: 87% TYPICAL AT 115V FULL LOAD *POWER GOOD SIGNAL: ON DELAY 100ms TO 500ms, OFF DELAY 1ms *OVER POWER PROTECTOIN *OVER VOLTAGE PROTECTOIN *SHORT CIRCUIT PROTECTION *OVER CURRENT PROTECTION *COOLING: ONE 80mm DC FAN *LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE VAC *ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D *EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B *SAFETY: TO MEET UL, CUL, TUV, CCC *ErP READY
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.